$6.40 a watt, no sales tax
Raised solar canopies
Panels on a raised frame high enough to walk under, so the walkway beneath stays clear and more of a flat roof carries panels.
Every job starts with a site survey.
37-32 61st Street, Woodside, NY 11377

On the roof
Low tilted frames on the flat roofs of Woodside's brick row houses, set out around the bulkhead, the hatch and the fire code's clear walkway.
AI-generated illustration. Not a real home or business.
A panel laid flat on a roof meets the summer sun well and the winter sun badly, and it holds puddles and grit on its glass. Tilted a little toward the south, it faces the low winter sun more squarely, and rain runs off its lower edge and takes most of the dust with it.
A tilted row casts a shadow behind it, and the lower the sun, the longer the shadow. So the rows are set apart, far enough that the row in front does not shade the next one through the middle of a winter day. That gap is why a framed panel takes more of a flat roof than the panel itself covers.
It is also why the frames are kept low. A low frame casts a short shadow, catches less wind, and stays down behind the parapet, where the street sees little of it.
AI-generated illustration. Not a real home or business.
The frames stand on pads laid on the roof covering, so each foot bears on a cushion and not on the membrane.
How the frames are held down against the wind, and what the roof deck under them can carry, is worked out by the engineer before anything is ordered. A flat roof in Queens sees gusts that come over the parapet and lift, and the drawings answer for every foot.
The covering under the frames matters as much as the frames. Rubber, modified bitumen, a white membrane or tar will all take them, but panels stay up for decades, so a covering near the end of its life is replaced before they go on, and the survey says whether yours is.
On a row-house roof the walkway runs from the front parapet to the back one, and everything else is fitted around it: the bulkhead or the hatch that is the way up, the skylight over the stairs, the vent pipes, the chimney, the drain. Each of those also casts a shadow or needs room around it to be reached, so the panels usually end up in blocks on either side of the walkway rather than in one sheet.
The parapet counts as well. A high one shades the row nearest it when the sun is low, and that row is set back from it for the same reason the rows are set apart from each other.
New York City's Fire Code keeps a clear walkway across a flat roof from the front of the house to the back, clear landings at the edge, and a clear strip at the ridge of a sloped roof, so that firefighters can work up there. Panels may not stand in them. That leaves less roof than you might expect, especially on a narrow row house. The engineer or architect who files the job draws the paths on the plans, and the planner allows for them only roughly.
A flat roof narrower than about eighteen feet keeps its walkway and leaves little room beside it; some of those can carry a canopy with the Fire Department's permission. We see those first.
The walkway is the same width on a narrow house as on a wide one, so on a narrow roof it takes a larger part of what there is, and the strips beside it may hold too few panels to carry the drawings and the permits. The planner stops there and leaves it to the office.
A canopy is the usual way round it: it lets the panels cross over the walkway instead of standing beside it.
One published rate per watt for frames, and the number of panels is what moves the total.
The number of panels is set by two things: how many your use calls for, and how many fit around the walkway. The planner works out both and prints the smaller one at each end of the range. Here is one worked through for a row house on the planner's own answers.
A worked example: a sizing range
A row house with low frames A 1930s brick row house in Woodside
The roof sizing planner's answer to these questions, at the published rate per watt. A sizing range is not an estimate, a quote or a proposal, and nothing on this site is an offer.
The price per watt covers the survey, the layout and the drawings, the panels, the inverters, the racking or the canopy, the wiring, the permits and the utility application, the install, the inspections and the monitoring set-up. It does not cover roof work, a new electrical service or a main panel upgrade, which are seen at the survey and priced in writing if they are needed.
$6.40 a watt, no sales tax
Panels on a raised frame high enough to walk under, so the walkway beneath stays clear and more of a flat roof carries panels.
Priced per watt by the mount, no sales tax
Houses with two to four homes under one roof: which meter the panels feed, who signs, and a roof shared by everybody under it.
Inside the price per watt
An hour on the roof and in the basement, then a layout that draws the clear paths first and the panels second.
Try the roof sizing planner: panels, kilowatts and the roof they take at the published rate, in about three minutes. Sending it to us books nothing.